Prosense BTN series gas detectors can reliably detect combustible, toxic, and oxygen gases in light and non-classified areas as a cost-effective solution.
Ask the Expert
• Sensor: Uses catalytic, electrochemical sensor specially designed to detect combustible, toxic and oxygen gases.
• Connection: 2 Alarm, 1 Fault relays output can be set predefined levels and can manage the other devices in case of any event.
• Entry: 3x PG11 cable entries
• Body: ABS Plastic body and IP54 protection class is suitable to low environmental conditions with.
• Output Options: Offers Modbus RS485 for specific applications
• Modbus: It allows to be integrated to SCADA systems easily via open source Modbus RS485(RTU) codes
Sensor Technology | Catalytic, Electrochemical, Semiconductor |
Output Signal | 2 Alarms and 1 Fault Relay |
Sensor Warm-Up | 60sec |
Response Time(T90) | Sensor Dependent |
Accuracy | %2 |
Operating Temperature | -20°C ~ +50°C |
Humidity | 5 ~ 95%RH |
Input | Min 10VDC - Max 28VDC - Nominal 24VDC |
Power Consumption | Max. 3W |
Cable Entry | 3 x PG11 |
IP Rating | IP54 |
Junction Box | ABS Plastic |
Sensor Head | ABS Plastic |
Dimensions/Weight | 150x94,5x58mm / 250gr |
Related Products
BTN Series Datasheet
BTN Series User Manual
CE Conformity
UKCA Conformity